Please use this identifier to cite or link to this item: https://ric.cps.sp.gov.br/handle/123456789/10571
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorALMEIDA, Rogéria Maria Alves de-
dc.contributor.authorTRASSI, Fernando-
dc.date.accessioned2022-12-05T14:17:22Z-
dc.date.available2022-12-05T14:17:22Z-
dc.date.issued2019-02-
dc.identifier.citationTRASSI, Fernando. Estudo em tecnovigilância: análise de recalls em equipamentos de fluoroscopia. Trabalho de conclusão de curso (Curso Superior de Tecnologia em Sistemas Biomédicos) - Faculdade de Tecnologia FATEC Bauru, Bauru, 2018.pt_BR
dc.identifier.urihttp://ric.cps.sp.gov.br/handle/123456789/10571-
dc.description.abstractAs instituições de saúde nem sempre conseguem prevenir da aquisição de produtos para saúde de má qualidade, a Tecnovigilância visa à monitoração pós comercialização dos produtos existentes no mercado, promovendo uma interação com seguimentos do setor e profissionais da saúde, a fim de perfazer o controle sanitário dos produtos comercializados com base em evidências. O estudo objetiva descrever as queixas técnicas e eventos adversos, relativo aos equipamentos de fluoroscopia notificados em Tecnovigilância por detentores de registro do produto, analisando as ocorrências em duas plataformas de pesquisa, no Brasil pelo sistema de Alertas da Agência Nacional de Vigilância Sanitária e no sistema americano Medical Device Recalls do Food and Drug Administration. Trata-se de um estudo descritivo, retrospectivo, com análise quantitativa e abordagem secundária dos eventos, realizada no período de abril de 2012 a julho de 2018. Foram obtidos 114 notificações de alertas ou recalls, similarmente o ano de 2015 apresentou o maior número de notificações de ação de campo entre os dois sistemas de pesquisa. O estudo constatou um total de 65 modelos entre famílias e séries divididos entre 8 fabricantes de equipamentos de fluoroscopia. Conclui-se, portanto, que a Tecnovigilância pode ser uma ferramenta de auxilio na indicativa de qualidade, o estudo de caso sobre equipamentos de fluoroscopia demonstrou que, aproximadamente 60% dos recalls estão relacionados a 4 padrões de ocorrências ou falhas, sendo que o problema relacionado ao software obteve o maior número de ações de campo, seguido por problema do tipo mecânico, problema da saída e problema envolvendo o material.pt_BR
dc.description.abstractHealth institutions are not always able to prevent the purchase of poor quality health products. Technovigilance aims at post-marketing monitoring of existing products in the market, promoting interaction with health sector professionals and health professionals, in order to sanitary control of marketed products based on evidence. The objective of this study was to describe the technical complaints and adverse events related to fluoroscopy equipment reported in Technovigilance by product registration holders, compiling the occurrences in two research platforms in Brazil by the National Sanitary Surveillance Agency Alerts system and in the system American Medical Device Recalls of the Food and Drug Administration. This is a descriptive, retrospective study, with a quantitative analysis and a secondary approach to the events, carried out from April 2012 to July 2018. A total of 114 notifications of alerts or recalls were obtained, similarly the year 2015 presented the highest number of notifications of field action between the two research systems. The study found a total of 65 models between families and series divided among 8 manufacturers of fluoroscopy equipment. It is concluded, therefore, that the Technovigilance can be a tool of assistance in the indicative of quality, the case study on fluoroscopy equipment demonstrated that, approximately 60% of the recalls are related to 4 patterns of occurrences or failures, being that the problem related to the software obtained the largest number of field actions, followed by mechanical problem, output problem and problem involving the material.pt_BR
dc.description.sponsorshipCurso Superior de Tecnologia em Sistemas Biomédicospt_BR
dc.language.isopt_BRpt_BR
dc.publisher196pt_BR
dc.subjectEquipamentos e provisões hospitalarespt_BR
dc.subjectEquipamentospt_BR
dc.subjectQualidade da produção (equipamentos)pt_BR
dc.subjectProdutos (qualidade)pt_BR
dc.subjectFluoroscopiapt_BR
dc.subjectTecnologiapt_BR
dc.subject.otherAmbiente e Saúdept_BR
dc.titleEstudo em tecnovigilância: análise de recalls em equipamentos de fluoroscopiapt_BR
dc.title.alternativeTechnovigilance study: analysis of recalls on fluoroscopy equipmentpt_BR
dc.typeArtigo científicopt_BR
Appears in Collections:Trabalhos de Conclusão de Curso

Files in This Item:
File Description SizeFormat 
sistemasbiomedicos_2018_2_fernandotrassi_estudoemtecnovigilancia.pdf
  Restricted Access
448.17 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.